- connection to emergency centrals with VdS2465 protocol VdS 2465-2:2018-02 (02)
- automatic dispatch to alternative centrals in case of non-available or busy destinations
- automatic selection of secondary communication paths / networks (model dependent)
- Identification number can be programmed individually for each central / each destination number
- free programmability of priority, address, subaddress, address extension, report type and assigned central for each input / voltage sensor / temperature sensor
- routine messages and alerts can be routed to different centrals / destination numbers
- all GSM models support contract cards and prepaid cards
- ISDN models support X.31 switched virtual circuits (SVC), X.31 permanent virtual circuits (PVC) and supervision of layer 1
- VdS message in the case of main power failure (model dependent)
- routine messages, accumulated status and block status messages
- outputs can be switched by the VdS central (after successful caller line identification)
- remote parametrisation
- cost control and notification if limits are exceeded
- comprehensive time controlled functions (eg for disabling / enabling inputs)
- automatic Daylight Saving Time handling
- 24x7 weekday / time table
- table for fixed and floating holidays
- table for sun rise / sun set times - flexible sequence control with flags and macros
- fast placing into operation without programming knowledge
- programming software CONNY included in delivery
- Made in Germany - developed and produced in Germany
IT190-VdS | IT191-VdS | IT70-VdS | IT251GI-VdS | IT251I-VdS | IT35G-VdS | IT35I-VdS | |
|
|
||||||
Power supply: | |||||||
Operating voltage | 230 V AC | 230 V AC | 24 V DC | 24 V DC | 24 V DC | 24 V DC | 24 V DC |
Max. current consumption | 50 mA | 50 mA | 200 mA | 350 mA | 350 mA | 80 mA | 80 mA |
Rechargable battery (not included in delivery) |
intern | intern | extern | extern | extern | - | - |
Charging circuit | yes | yes | yes | yes | yes | - | - |
Inputs: | |||||||
Digital switching inputs | 6 | 6 | 4 | 20 | 20 | 2 | 2 |
Voltage inputs 0..10 V | max.2 | max.2 | max. 4 | - | - | - | - |
Current inputs 0..20 mA | max.2 | max. 2 | max. 4 | - | - | - | - |
Temperature inputs | 1 | 1 | 2 | 3 | 3 | - | - |
230V inputs | - | 1 | - | - | - | - | - |
Outputs: | |||||||
Relais outputs 48 V | 1 | 1 | 2 | 6 | 6 | 1 | 1 |
Relais outputs 230 V | - | 1 | - | - | - | - | - |
Interfaces: | |||||||
USB | yes | yes | yes | yes | yes | - | - |
RS232 | optional | optional | optional | yes | yes | yes | yes |
Communication networks: | |||||||
GSM | yes | yes | yes | yes | - | yes | yes |
Assembly option LTE (4G) | yes | yes | yes | yes | - | in preparation | - |
ISDN / router with S0 interface | - | - | - | yes | yes | - | - |
Protection class | IP65 | IP65 | IP20 | IP20 | IP20 | IP20 | IP20 |
Environmental temperature | -40..+70° C | -40..+70° C | -20..+70° C | -20..+70° C | -20..+70° C | -20..+70° C | -20..+70° C |
Humidity | 0..100 % | 0..100 % | 0..70 % | 0..70 % | 0..70 % | 0..70 % | 0..70 % |
Dimensions (L x W x H in mm) | 150 x 180 x 35 | 150 x 180 x 35 | 86 x 70 x 58 | 86 x 155 x 58 | 86 x 155 x 58 | 94 x 35 x 76 | 94 x 35 x 76 |